![]() ![]() Connect the ACTSmart2 and the SmartLock as in the diagram below and power up. The Data line from the SmartLock to the ACTSmart2 must be less than 30m.ġ. Ensure that the Door Release wires are not accessible to an attacker. This prevents a short from +12V to 0V on the ACTSmart2 side of the door from deenergising the Maglock. Some PSUs can accomodate the Smartlock directly, otherwise drill holes to suit the SmartLock, (5mm drill bit required).įor a Maglock, two fused outputs are required - one fused output for the ACTSmart2 and another for the Smartlock and Maglock. When the input is activated, the door will open for the Door Relay Time programmed into the ACTSmart.ĪCT recommends installing the SmartLock inside the Power Supply Unit. The normally open door release button should be connected to the SmartLock. Since the SmartLock is inside a secure area, an attacker has no access to the lock control relay. The SmartLock learns an ID code from the ACTSmart2 and only operates its' relay when a valid card or PIN is presented to the ACTSmart2. The SmartLock improves the security of ACTSmart2 installations by allowing the installer to locate the lock control relay inside a secure area.